Skip to main content

Osteofit LLC – Acetabular Reamers

The Accuracy of Acetabular Reaming in Total Hip Replacement

The stability of cementless cups depends upon the fit of the shell in the reamed acetabulum. Consequently, over-reaming can lead to increased micromotion or traumatic disruption with loss of cementless fixation. Therefore, it is critical that the surgeon knows the true size of the reamed acetabulum before implanting a cementless acetabular cup. In this study, […]

Assessment of Bone Viability After Heat Trauma

Abstract In the present investigation a comparison was made between conventional histology, histochemistry, and vital microscopy for assessment of heat induced bone tissue injury. The extent of the bone damage around a burr hole or after heating fibular bone samples in saline solutions of various temperatures was evaluated by means of histology and histochemistry, using […]

Deeper Central Reaming May Enhance Initial Acetabular Shell Fixation

Deeper Central Reaming May Enhance Initial Acetabular Shell Fixation Background: The initial stability of press-fit acetabular components is partially determined by the reaming technique. Nonhemispherical (NHS) acetabular shells, which have a larger radius at the rim than the dome, often require larger reaming preparations than the same-sized hemispherical (HS) shells. Furthermore, deeper central reaming may […]

Determinants of the primary stability of cementless acetabular cup implants: A 3D finite element study

Determinants of the primary stability of cementless acetabular cup implants: A 3D finite element study Abstract Primary stability of cementless implants is crucial for the surgical success and long–term stability. However, primary stability is difficult to quantify in vivo and the biomechanical phenomena occurring during the press–fit insertion of an acetabular cup (AC) implant are still poorly understood. The […]

Initial stability of cementless acetabular cups: press-fit and screw fixation interaction – an invitro biomechanical study

Abstract Background Press-fit and screw fixation are important technical factors to achieve initial stability of a cementless acetabular cup for good clinical results of total hip arthroplasty. However, how these factors affect one another in initial cup fixation remains unclear. Therefore, this study aimed to evaluate the mutual influence between press-fit and screw fixation on […]

Accuracy of Acetabular Reamers in Total Hip Arthroplasty

Accuracy of Acetabular Reamers in Total Hip Arthroplasty P Vaughan    P Johnston    G Keene Abstract Introduction: Serial reamers of incremental diameter are used in the preparation of the acetabulum in Total Hip Arthroplasty. If the reamer is blunt, then the size of the reamed acetabulum may not accurately represent the size of the last reamer used. […]