Osteofit LLC – Acetabular Reamers

Cementless socket fixation based on the “press-fit” concept in total hip arthroplasty

February 2002 Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca 69(1):8-15 Cementless socket fixation based on the “press-fit” concept in total hip arthroplasty E W Morscher, K-H Widmer, H Bereiter Abstract The key problem of implant fixation in THR is stress distribution, i.e. load transmission between bone and implant. The closer the load transfer is to the […]

The Accuracy of Acetabular Reaming in Total Hip Replacement

The stability of cementless cups depends upon the fit of the shell in the reamed acetabulum. Consequently, over-reaming can lead to increased micromotion or traumatic disruption with loss of cementless fixation. Therefore, it is critical that the surgeon knows the true size of the reamed acetabulum before implanting a cementless acetabular cup. In this study, […]

Assessment of Bone Viability After Heat Trauma

Abstract In the present investigation a comparison was made between conventional histology, histochemistry, and vital microscopy for assessment of heat induced bone tissue injury. The extent of the bone damage around a burr hole or after heating fibular bone samples in saline solutions of various temperatures was evaluated by means of histology and histochemistry, using […]

Determinants of the primary stability of cementless acetabular cup implants: A 3D finite element study

Determinants of the primary stability of cementless acetabular cup implants: A 3D finite element study Abstract Primary stability of cementless implants is crucial for the surgical success and long–term stability. However, primary stability is difficult to quantify in vivo and the biomechanical phenomena occurring during the press–fit insertion of an acetabular cup (AC) implant are still poorly understood. The […]

Deeper Central Reaming May Enhance Initial Acetabular Shell Fixation

Deeper Central Reaming May Enhance Initial Acetabular Shell Fixation Background: The initial stability of press-fit acetabular components is partially determined by the reaming technique. Nonhemispherical (NHS) acetabular shells, which have a larger radius at the rim than the dome, often require larger reaming preparations than the same-sized hemispherical (HS) shells. Furthermore, deeper central reaming may […]

Initial stability of cementless acetabular cups: press-fit and screw fixation interaction – an invitro biomechanical study

Abstract Background Press-fit and screw fixation are important technical factors to achieve initial stability of a cementless acetabular cup for good clinical results of total hip arthroplasty. However, how these factors affect one another in initial cup fixation remains unclear. Therefore, this study aimed to evaluate the mutual influence between press-fit and screw fixation on […]